The GPCA is a metal-sealed pressure controller well suited for a wide variety of applications requiring pressure control capability from 500 Torr to 100 psi Full Scale. It incorporates the latest in digital flow control electronics along with a well proven, thermally stable pressure sensor and mechanical design.
The following options are available for GPCA General Purpose Pressure Controllers
Ordering Code Example: GPCAA13TR62UT10
| Configuration Option | Option Code |
|---|---|
|
GPCA Integrated Upstream Pressure Controller |
GPCA |
Sensor Type |
|
| Absolute | A |
Pressure Range Full Scale |
|
| 500 Torr | 52T |
| 1000 Torr | 13T |
| 2000 Torr | 23T |
| 60 psia | 61P |
| 100 psia | 12P |
| 1000 mBar | 13M |
| 2000 mBar | 23M |
| 5000 mBar | 53M |
| 100 kPa | 12K |
| 200 kPa | 22K |
| 600 kPa | 62K |
Fittings |
|
| Swagelok 4 VCR | R |
| ¼ in. Swagelok | S |
| C-Seal | C |
| W-Seal (1.125 in.) | H |
Communications |
|
| DeviceNet | 6 |
| EtherCAT | 8 |
| RS485 (ASCII) | 5 |
Orifice Size |
|
| A (50 sccm) | A |
| #1 (200 sccm) | 1 |
| #2 (1000 sccm) | 2 |
| #3 (5000 sccm) | 3 |
| #4 (10000 sccm) | 4 |
| #5 (20000 sccm) | 5 |
| #6 (30000 sccm) | 6 |
| #7 (50000 sccm) | 7 |
Pressure Control |
|
| Upstream (inlet) | U |
| Downstream (outlet) | D |
Valve Seal Material |
|
| Teflon | T1 |
Reserved |
|
| Standard | 0 |
Firmware |
|
| Customer must specify firmware version at time of order | 10 |
The GPCA digitally controlled pressure controller is available with EtherCAT®, DeviceNet™ or RS485 digital I/O. The digital control electronics utilize the latest in MKS control algorithms providing fast and repeatable response to set point throughout the device control range. Typical response times are less than 1 second dependent on installation conditions. Included is a digital calibration that yields 1% of set point accuracy.
The GPCA metal-sealed pressure controller with its 10 microinch, electropolished surface finish is well suited for use in high purity process applications. The GPCA is available with a normally closed valve and may be configured for controlling either inlet pressure to the device or the outlet pressure of the device.