631F 1-1000 Torr Heated (150 or 200°C) Absolute Baratron® Capacitance Manometer
Model: 631F
631F 1-1000 Torr Heated (150 or 200°C) Absolute Baratron® Capacitance Manometer
Model: 631F

Overview
Overview
The 631F 1-1000 Torr, Heated (150 or 200°C) Absolute Baratron® Capacitance Manometer, operating at very high internal temperatures, minimizes the deposition of process byproducts within the sensor—nearly eliminating output drift caused by contamination. Its available operating temperatures are 150°C or 200°C, permitting use in the most demanding vacuum processes in semiconductor manufacturing such as metal etching and nitride film chemical vapor deposition (CVD). Its new packaging reduces the amount of installation space needed by at least 40%, making it even easier to design into new systems or retrofit into existing equipment. The 631F is completely self-contained, requiring only input power of ±15VDC for operation. No separate electronics modules are used, which both reduces the amount of installation space needed and provides better performance due to elimination of noise generating interconnecting cables. Its Inconel® sensor offers extremely high resistance to corrosion, and its overpressure rating of 45 psia ensures good repeatability and stability regardless of the system operating conditions. The Type 631F high-performance analog electronics also include fail-safe over temperature protection and LED status lamps to indicate its operating state. An internally-mounted set of two (2) UL-approved solid-state trip relays for pressure and one (1) UL-approved electromechanical relay for heater failure is also available, allowing the manometer to control external equipment or components. The pressure trip relays may be adjusted by the user independently at atmospheric pressure, eliminating the need for vacuum pumps during setpoint adjustment.
Technical Specs
- TypePressure Transducer
- Measurement TypeAbsolute
- Full Scale Range1000 Torr
- Sensor Temperature200°C
- Accuracy0.50% of Reading
- Fitting Type2.0 in. TriClover
- Analog Output0 - 10 VDC
- Analog Connector15-pin D-sub
- Trip RelaysTrip Point A Below Setpoint, Trip Point B Above Setpoint
- Resolution0.01% of Full Scale
- Zero Temperature Coefficient0.004% of Full Scale/°C (0.008% of Full Scale/°C for 1 Torr range) for 150°C products, 0.008% of Full Scale/°C (0.016% of Full Scale/°C for 1 Torr range) for 200°C products
- Span Temperature Coefficient0.02% of Reading/°C
- Response Time50 msec
- Warm-up Time4 hours or less
- Internal Volume6.3 cc
- Operating Temperature Range15-50°C
- Overpressure Limit45 psia
- Exposed MaterialsInconel® or Incoloy® nickel alloys
- Power Requirements± 15VDC (±5%) @ 1.0 amps max
- UnitskPa
- Ambient Airflow Requirements150°C Models 50 ft/min for ambient temperatures of 45 - 50°C, 200°C Models 150 ft/min for ambient temperatures of 40 - 50°C
- ComplianceCE
Technical Specs
- TypePressure Transducer
- Measurement TypeAbsolute
- Full Scale Range1000 Torr
- Sensor Temperature200°C
- Accuracy0.50% of Reading
- Fitting Type2.0 in. TriClover
- Analog Output0 - 10 VDC
- Analog Connector15-pin D-sub
- Trip RelaysTrip Point A Below Setpoint, Trip Point B Above Setpoint
- Resolution0.01% of Full Scale
- Zero Temperature Coefficient0.004% of Full Scale/°C (0.008% of Full Scale/°C for 1 Torr range) for 150°C products, 0.008% of Full Scale/°C (0.016% of Full Scale/°C for 1 Torr range) for 200°C products
- Span Temperature Coefficient0.02% of Reading/°C
- Response Time50 msec
- Warm-up Time4 hours or less
- Internal Volume6.3 cc
- Operating Temperature Range15-50°C
- Overpressure Limit45 psia
- Exposed MaterialsInconel® or Incoloy® nickel alloys
- Power Requirements± 15VDC (±5%) @ 1.0 amps max
- UnitskPa
- Ambient Airflow Requirements150°C Models 50 ft/min for ambient temperatures of 45 - 50°C, 200°C Models 150 ft/min for ambient temperatures of 40 - 50°C
- ComplianceCE