Heated Capacitance Manometer, 200°C, 10 Torr, 0.5%, 8 VCR-F, DB15, Below Set Point Relays

Technical Specs

  • Type
    Vacuum/pressure Transducer
  • Measurement Type
    Absolute
  • Full Scale Range
    10 Torr
  • Sensor Temperature
    200°C
  • Accuracy
    0.50% of Reading
  • Fitting Type
    8 VCR female
  • Analog Output
    0-10 VDC
  • Analog Connector
    15-pin D-sub
  • Trip Relays
    2
  • Relay Mode
    Energizes below set point
  • Relay Contact Rating
    0.20 amps @ 30 VDC
  • Resolution
    0.01% of Full Scale
  • Zero Temperature Coefficient
    0.008% of Full Scale/°C (0.016% of Full Scale/°C for 1 Torr range)
  • Span Temperature Coefficient
    0.02% of Reading/°C
  • Response Time
    50 msec
  • Warm-up Time
    4 hours or less
  • Internal Volume
    6.3 cc
  • Operating Temperature Range
    15-50°C
  • Overpressure Limit
    45 psia
  • Exposed Materials
    Inconel® or Incoloy® nickel alloys
  • Power Requirements
    ± 15VDC (±5%) @ 1.0 amps max
  • Ambient Airflow Requirements
    150 ft/min for ambient temperatures of 40 - 50°C
  • Compliance
    CE

Need help?