Technical Specs

  • Type
    Digital Pressure Transducer
  • Sensor Type
    Short tube standard sensor
  • Measurement Type
    Absolute
  • Sensor Temperature
    Ambient
  • Full Scale Range
    0.25 Torr
  • Fitting Type
    2.75 in. OD CF
  • Analog Output
    0-10 VDC
  • Accuracy
    0.25% of Reading
  • Zero Temperature Coefficient
    Unheated Models: 10 - 1000 Torr 0.005% of Full Scale/°C, 2 Torr 0.010% of Full Scale/°C, 1 Torr 0.015% of Full Scale/°C, Heated Models: 1 - 1000 Torr 0.002% of Full Scale/°C 45°C, <1 Torr 0.005% of Full Scale/°C, 80 and 100°C <1 Torr 0.010% of Full Scale/°C
  • Span Temperature Coefficient
    Unheated Models: 0.04% of Reading/°C, Heated Models: 0.02% of Reading/°C
  • Resolution
    0.001% Full Scale on digital output
  • Volume
    6.3 cc
  • Overpressure Limit
    45 psia (310 kPa)
  • Exposed Materials
    Inconel and Incoloy nickel alloys (Some optional fittings are made from 300-series stainless steel)
  • Calibration Orientation
    Vertical
  • Interface
    DeviceNet™, Group 2
  • Level of Filtering
    Adjustable via user software
  • Digital Functions
    Read pressure, set digital trip points and hysteresis, select units (Torr, Pa, mbar, in H2O, psi), set zero, reset factory defaults, monitor transducer trip point status, change user tags and device address
  • Network Topology
    Linear (trunkline/dropline) power and signal on same network cable
  • Network Size
    64 nodes maximum
  • Data Rate Network Length
    User-selectable data rate: 125 kbps and 500 m (1,640 ft), 250 kbps and 250 m (820 ft), or 500 kbps and 100 m (328 ft)
  • Data Rate Switch
    4 positions: 125, 250, 500, PGM (programmable via network)
  • MAC ID Switches
    2 switches, 10 positions: 0,0 - 6,3 are hardware ID numbers, 7,0 - 9,9 are software ID numbers, 6,4 - 6,9 are unused and if selected will default - hard ID number 6,3
  • Network Message Control
    Master/slave information flow
  • Power Requirements
    Unheated Models: 11 - 25 VDC @≤5 watts, 45°C Models: Operation with heater requires 18 - 25 VDC @≤15 watts, 80°C & 100°C Models: Operation with heater requires 18 - 25 VDC @≤25 watts Heated Models Can provide only network communications at <18 VDC (i.e. heater does not operate if input voltage is <18 VDC)
  • Units
    kPa
  • Compliance
    CE

Technical Specs

  • Type
    Digital Pressure Transducer
  • Sensor Type
    Short tube standard sensor
  • Measurement Type
    Absolute
  • Sensor Temperature
    Ambient
  • Full Scale Range
    0.25 Torr
  • Fitting Type
    2.75 in. OD CF
  • Analog Output
    0-10 VDC
  • Accuracy
    0.25% of Reading
  • Zero Temperature Coefficient
    Unheated Models: 10 - 1000 Torr 0.005% of Full Scale/°C, 2 Torr 0.010% of Full Scale/°C, 1 Torr 0.015% of Full Scale/°C, Heated Models: 1 - 1000 Torr 0.002% of Full Scale/°C 45°C, <1 Torr 0.005% of Full Scale/°C, 80 and 100°C <1 Torr 0.010% of Full Scale/°C
  • Span Temperature Coefficient
    Unheated Models: 0.04% of Reading/°C, Heated Models: 0.02% of Reading/°C
  • Resolution
    0.001% Full Scale on digital output
  • Volume
    6.3 cc
  • Overpressure Limit
    45 psia (310 kPa)
  • Exposed Materials
    Inconel and Incoloy nickel alloys (Some optional fittings are made from 300-series stainless steel)
  • Calibration Orientation
    Vertical
  • Interface
    DeviceNet™, Group 2
  • Level of Filtering
    Adjustable via user software
  • Digital Functions
    Read pressure, set digital trip points and hysteresis, select units (Torr, Pa, mbar, in H2O, psi), set zero, reset factory defaults, monitor transducer trip point status, change user tags and device address
  • Network Topology
    Linear (trunkline/dropline) power and signal on same network cable
  • Network Size
    64 nodes maximum
  • Data Rate Network Length
    User-selectable data rate: 125 kbps and 500 m (1,640 ft), 250 kbps and 250 m (820 ft), or 500 kbps and 100 m (328 ft)
  • Data Rate Switch
    4 positions: 125, 250, 500, PGM (programmable via network)
  • MAC ID Switches
    2 switches, 10 positions: 0,0 - 6,3 are hardware ID numbers, 7,0 - 9,9 are software ID numbers, 6,4 - 6,9 are unused and if selected will default - hard ID number 6,3
  • Network Message Control
    Master/slave information flow
  • Power Requirements
    Unheated Models: 11 - 25 VDC @≤5 watts, 45°C Models: Operation with heater requires 18 - 25 VDC @≤15 watts, 80°C & 100°C Models: Operation with heater requires 18 - 25 VDC @≤25 watts Heated Models Can provide only network communications at <18 VDC (i.e. heater does not operate if input voltage is <18 VDC)
  • Units
    kPa
  • Compliance
    CE