625H 1-1000 Torr, Heated (100°C) Absolute Baratron® Capacitance Manometers with Trip Points
Model: 625H
625H 1-1000 Torr, Heated (100°C) Absolute Baratron® Capacitance Manometers with Trip Points
Model: 625H

Overview
Overview
The 625H Heated (100°C) Absolute Baratron® Capacitance Manometer with Trip Points features two user adjustable process trip point relays, each with an adjustment range from 0.1% to 100% of Full Scale or voltage equivalent 0.01 to 10 VDC. Dual color LEDs indicate relay status. Typical relay uses include pump cross-over and valve activation. It is temperature controlled at 100°C, and is available in full scale ranges of 1, 10, 20, 100, 500, and 1000 Torr. The 625H operates with ±15 VDC (±5%) input at <600 mA, and provides an output of 0 to 10 VDC linear with pressure. The 625H sensor exposes only Inconel® to the process permitting the use with corrosive or dirty gases. Measurements are independent of gas composition. The modern stainless steel enclosure provides a cleanroom compatible product.
Technical Specs
- TypePressure Transducer
- Measurement TypeAbsolute
- Sensor Temperature100°C
- Full Scale Range1000 Torr
- Accuracy0.25% of Reading
- Resolution0.001% of Full Scale
- Fitting TypeNW25 ISO-KF
- Analog Output0 - 10 VDC
- Analog ConnectorTerminal Block Adapter
- Zero Temperature Coefficient0.002% of Full Scale/°C
- Span Temperature Coefficient0.02% of Reading/°C
- Ambient Operating Temperature15-50°C
- Volume6.3 cc
- Warm-up Time2 hours
- Overpressure Limit45 psia (310 kPa)
- Exposed MaterialsInconel and/or 316 stainless steel
- Power Requirements±15 VDC ±5% @ 0.60 Amps (max.)
- Trip Points2
- Trip Point Level Signal0.01 to 10 VDC for each trip point
- Relay Contact RatingsSPDT contacts rated at 1 Amp @ 30 VDC or 0.5 Amp @ 30 VAC resistive
- ComplianceCE
Technical Specs
- TypePressure Transducer
- Measurement TypeAbsolute
- Sensor Temperature100°C
- Full Scale Range1000 Torr
- Accuracy0.25% of Reading
- Resolution0.001% of Full Scale
- Fitting TypeNW25 ISO-KF
- Analog Output0 - 10 VDC
- Analog ConnectorTerminal Block Adapter
- Zero Temperature Coefficient0.002% of Full Scale/°C
- Span Temperature Coefficient0.02% of Reading/°C
- Ambient Operating Temperature15-50°C
- Volume6.3 cc
- Warm-up Time2 hours
- Overpressure Limit45 psia (310 kPa)
- Exposed MaterialsInconel and/or 316 stainless steel
- Power Requirements±15 VDC ±5% @ 0.60 Amps (max.)
- Trip Points2
- Trip Point Level Signal0.01 to 10 VDC for each trip point
- Relay Contact RatingsSPDT contacts rated at 1 Amp @ 30 VDC or 0.5 Amp @ 30 VAC resistive
- ComplianceCE