Absolute Pressure Transducer, 2 Trip Points, 100 Torr, 8 VCR-F, 5-pin Terminal

Technical Specs

  • Type
    Vacuum/pressure Transducer
  • Measurement Type
    Absolute
  • Full Scale Range
    100 Torr
  • Sensor Temperature
    Ambient
  • Fitting Type
    8 VCR female
  • Analog Output
    0-10 VDC
  • Accuracy
    0.25% of Reading
  • Electrical Connector
    Terminal block
  • Zero Temperature Coefficient
    0.005% of Full Scale/Ā°C
  • Span Temperature Coefficient
    0.04% of Reading/Ā°C
  • Operating Temperature Range
    0-50Ā°C
  • Resolution
    0.001% of Full Scale
  • Volume
    6.3 cc
  • Overpressure Limit
    45 psia (310 kPa)
  • Exposed Materials
    IncoloyĀ® and InconelĀ®
  • Warm-up Time
    30 minutes
  • Trip Points
    2
  • Trip Point Relay Rating
    SPDT, 1 Amp @ 30 VDC or 0.5 Amp @ 30 VAC resistive
  • Power Requirements
    Ā±15 VDC Ā±5% @ 75 mA
  • Compliance
    CE

Need help?

Contact an Applications Specialist by sending us an email