AIRGARD® HPA/TIC
Model: AIRGARD-HPA-TIC
AIRGARD® HPA/TIC
Model: AIRGARD-HPA-TIC

Overview
Overview
AIRGARD® HPA/TIC, Ambient FTIR Air Analyzer
AIRGARD® HPA/TIC ambient air analyzer is an ultra-sensitive, Fourier Transform Infrared Spectroscopy (FTIR) based gas analyzer designed to rapidly detect toxic gases. This analyzer is capable of detecting parts per billion (ppb) levels of most Hazardous Production Materials (HPMs) and Toxic Industrial Chemicals (TICs) below Threshold Limit Values (TLV) and/or Immediately Dangerous to Life or Health (IDLH) levels within 20 seconds.
AIRGARD analyzer has been thoroughly tested by the Department of Defense for its sensitivity, specificity, response time, and immunity to false positive alarms caused by the sensing of, and alarming to, everyday benign, non-toxic solvents and industrial chemicals. This immunity to false alarms prevents unwarranted evacuation of buildings, associated interruptions of business and emergency notifications when no toxic materials are present.
Applications
- Continuous detection of HPMs and TICs
- Airborne Molecular Contamination (AMC)
- Emergency Response (ERT) gas monitoring
- Ambient air, exhausted enclosures, abatement systems, gas delivery (gas cabinets and VMBs)
- Semiconductor, Solar, LED manufacturing
- Research laboratories – university, government, nanotech
Technical Specs
- TypeFTIR Analyzer
- Measurement TechniqueFTIR Spectrometry
- Measurable Gases & VaporsHazardous Production Material Nearly all organic and inorganic gases except diatomics and noble gases (H2 , F2 , Cl2 , N2 , O2 , Br2 , He, Ne, Ar, Kr, Xe)
- Measurable RangeConcentration settings between 1ppb and 100% full scale
- Enclosure19 in.wall mount chassis
- Dimensions18.4 x 25.4 x 7.5 in. (46.7 x 64.5 x 19.1 cm) (width x height x depth)
- Power Requirements120 or 240 VAC, 50/60Hz, 3 amps
- Weight75 lbs. (34.1kg)
- Fittings3/8 in. Swagelok®
- Tubing0.25 in. stainless steel and Tygon®
- Operating Temperature10-40°C
- Operating HumidityUp to 65%
- Laser SafetyClass 1 laser product contains a Class 3R laser with continuous wave output at 850 nm
Technical Specs
- TypeFTIR Analyzer
- Measurement TechniqueFTIR Spectrometry
- Measurable Gases & VaporsHazardous Production Material Nearly all organic and inorganic gases except diatomics and noble gases (H2 , F2 , Cl2 , N2 , O2 , Br2 , He, Ne, Ar, Kr, Xe)
- Measurable RangeConcentration settings between 1ppb and 100% full scale
- Enclosure19 in.wall mount chassis
- Dimensions18.4 x 25.4 x 7.5 in. (46.7 x 64.5 x 19.1 cm) (width x height x depth)
- Power Requirements120 or 240 VAC, 50/60Hz, 3 amps
- Weight75 lbs. (34.1kg)
- Fittings3/8 in. Swagelok®
- Tubing0.25 in. stainless steel and Tygon®
- Operating Temperature10-40°C
- Operating HumidityUp to 65%
- Laser SafetyClass 1 laser product contains a Class 3R laser with continuous wave output at 850 nm
Resources & Downloads
Literature
AIRGARD® HPA/TIC Ambient Air Analyzer(184.2 kB, PDF)