Pressure Transducer, Absolute, 1000 Torr, 8 VCR-F, 100C, 0-10 VDC, DB15

Technical Specs

  • Type
    Pressure Transducer
  • Sensor Type
    Capacitance Manometer
  • Measurement Type
    Absolute
  • Full Scale Range
    1000 Torr
  • Sensor Temperature
    100°C
  • Fitting Type
    8 VCR female
  • Analog Output
    0 - 10 VDC
  • Electrical Connector
    15-pin D-sub
  • Accuracy
    0.50% of Reading
  • Response Time
    <75 msec
  • Zero Temperature Coefficient
    0.010% of Full Scale/°C
  • Span Temperature Coefficient
    0.040% of Full Scale/°C
  • Operating Temperature Range
    15 - 50°C
  • Overpressure Limit
    45 psia or 2 x Full Scale range, whichever is greater
  • Burst Pressure
    10 x Full Scale range or 90 psi, whichever is greater
  • Exposed Materials
    Inconel®
  • Power Requirements
    ± 15 VDC