Cold Cathode Vacuum Transducer, Inverted Magnetron, NW40 ISO-KF

Technical Specs

  • Type
    Inverted Magnetron Transducer
  • Sensor Type
    Cold Cathode
  • Installation Orientation
    Any
  • Measurement Range
    3.0 x 10-10 - 5.0 x 10-3 Torr
  • Set Point Range
    1.0 x 10-9 - 1.0 x 10-3 Torr
  • Repeatability
    5% of Reading (approximate)
  • Calibration Gas
    Air/Nitrogen
  • Fitting Type
    ISO-KF
  • Flange Size
    NW40
  • Operating Temperature
    0 - 50°C (32 - 122°F)
  • Bake Out Temperature
    400°C (752°F) without electronics
  • Relative Humidity
    80% maximum for temperatures less than 31°C, decreasing linearly to 50% maximum at 40°C
  • Set Point Response
    <50 msec (0 - 99%) for Dp from 5.0 x 10-8 - 3.0 x 10-4 Torr
  • Relays
    1 relay set point
  • Relay Contact Rating
    1 Amp @ 30 VDC, resistive
  • Power Requirements
    14 - 30 VDC, 3 Watts max.
  • Exposed Materials
    304 and 302 stainless steel, aluminum, Inconel® X-750, glass, alumina ceramic
  • Case Material
    ABS plastic, UL94-5V flame rating (with conductive coating)
  • Internal Volume
    0.9 in3 (15.0 cm3) max.
  • Display
    Set point (red), high voltage (yellow), power (green)
  • Output Voltage
    1.5 - 8.7 VDC, 30 Ohm maximum output impedance
  • Compliance
    CE

Need help?

Contact an Applications Specialist by sending us an email