Gas Analyzer, Tunable Filter Spectroscopy, Natural Gas Pipelines

Technical Specs

  • Type
    TFS Gas Analyzer
  • Measurement Technique
    Tunable Filter Spectroscopy
  • Measurement Ranges
    CH4: 50-100%
    C2H6: 0-20%
    C3H8: 0-10%
    iC4H10: 0-5%
    nC4H10: 0-5%
    iC5 + neoC5 (as iC5): 0-2%
    n-Hexane: 0-2%
    CO2:0-20%
    Balance
    High Heating Value (HHV)
    Low Heating Value (LHV)
    Specific Gravity
    Wobbe Index (WI) (per ISO 6976: 2016)
  • Repeatability
    nC6, nC4+nC5 Channels: <0.1 mol%; All others: <0.05%
    HHV, LHV & WI: <0.3% of Reading or <0.15 MJ/m3 (greater of)
    Specific Gravity: <0.06% of Reading
  • Accuracy
    Gas Channels: ±0.25 mol% or ±0.5% of Full Scale (greater of)
    HHV, LHV & WI: ±0.7% of Reading or ±0.25 MJ/m3 (greater of)
    Specific Gravity: ±0.5% of Reading

Need help?