Sorry, this product is no longer offered for sale. The recommended replacement product is E29H.1TBFL1B.
E29F 0.02-1000 Torr Heated (45 or 100°C) Baratron® Capacitance Manometers with Etch Sensor
Model: E29F.1TBFL1B
E29F 0.02-1000 Torr Heated (45 or 100°C) Baratron® Capacitance Manometers with Etch Sensor
Model: E29F.1TBFL1B

Overview
Overview
The E29F.1TBFL1B Baratron® Ethernet-Enabled, 100°C Heated Absolute Capacitance Manometer, with an Etch Sensor features 0.1 Torr full scale pressure measurement with 0.5% accuracy, vertical calibration, and a Swagelok® 8 female VCR® fitting. It has efficient temperature control electronics to provide superior long-term stability and repeatability. Based on the well-established Baratron capacitance manometer technology, the sensor’s wetted surfaces are Inconel® for corrosion resistance. The modern stainless steel enclosure provides a cleanroom compatible product. The E29F is fully compatible with earlier MKS’ Types 629A, 629B, 629D, E29B, and E29D Baratron capacitance manometers, as well as many competitive products.
Technical Specs
- TypeVacuum Pressure Transducer
- Sensor TypeCapacitance Manometer with Etch Sensor
- Measurement TypeAbsolute
- Sensor Temperature100°C
- Full Scale Range0.1 Torr
- Accuracy0.5% of Reading
- Resolution0.001% of Full Scale
- Fitting Type8 VCR female
- Analog Output0 - 10 VDC
- Analog Connector9-pin D-sub with Thread Locks
- CalibrationVertical
- Zero Temperature Coefficient0.01% of Full Scale/°C
- Span Temperature Coefficient0.02% of Reading/°C
- Operating Temperature Range15° to 50°C
- Volume6.3 cc
- Warm-up Time4 hours
- Overpressure Limit45 psia (310 kPa)
- Exposed MaterialsInconel®
- Power Requirements±15 VDC ±5% @ 0.5 Amps
- IndicatorsNo
- ComplianceCE
Technical Specs
- TypeVacuum Pressure Transducer
- Sensor TypeCapacitance Manometer with Etch Sensor
- Measurement TypeAbsolute
- Sensor Temperature100°C
- Full Scale Range0.1 Torr
- Accuracy0.5% of Reading
- Resolution0.001% of Full Scale
- Fitting Type8 VCR female
- Analog Output0 - 10 VDC
- Analog Connector9-pin D-sub with Thread Locks
- CalibrationVertical
- Zero Temperature Coefficient0.01% of Full Scale/°C
- Span Temperature Coefficient0.02% of Reading/°C
- Operating Temperature Range15° to 50°C
- Volume6.3 cc
- Warm-up Time4 hours
- Overpressure Limit45 psia (310 kPa)
- Exposed MaterialsInconel®
- Power Requirements±15 VDC ±5% @ 0.5 Amps
- IndicatorsNo
- ComplianceCE
Resources & Downloads
Drawings & CADs
E29 Dimensional Drawing(126.9 kB, PDF)