The Cirrus™3-XD Compact Benchtop and Rack-mounted Atmospheric Systems with V-lens™ Technology are designed for researchers and engineers who need to work beyond the limits of conventional quadrupole mass spectrometry gas analysis - to more easily detect and monitor trace gases - the Cirrus™ 3-XD Single-quadrupole MS Gas Analyzer delivers a unique analytical advantage for "eXtreme Detection" capability. The proven Cirrus™ Quadrupole MS platform now utilizes patented, V-lens™ ion optics with a double-focusing and deflection capability - to produce a consistently low baseline for any gas species - enabling trace level detection with greater clarity and confidence than ever before. With its versatile, compact design and powerful, automatable software control, the Cirrus™ 3-XD system provides a new level in performance, robustness and ease-of-use for the most challenging trace gas analyses. Cirrus™ gas analysis systems are ideal for on-line monitoring and analysis of gases and gas mixtures including trace contaminants in process gases, solvent vapors, hydrocarbons, atmospheric and inorganic gas species (including corrosives), freons and noble gases. Cirrus™ Single-quadrupole Mass Spectrometer Gas Analyzer systems are easy to install and operate, featuring automatic start-up and shut-down routines as well as built-in vacuum and heater interlocking for system protection. Cirrus™ 3-XD systems are manufactured from quality field proven materials which maximize reliability and uptime. Particular consideration has been paid to ease of service and maintenance.
180°C for bake out, 80°C setting for operation at elevated temperatures (vacuum chamber & inlet interface)
Inlet
2.0 m long with 0.25 in. Swagelok® end connection, heated to 150°C (optional heating to 300°C, with stainless steel only). Standard fused silica and optional stainless steel.
Gas Consumption
20 ml/min, lower uptake rate capillaries options are available
Sample Pressure
1 bar nominal
Pumping System
High compression turbo-molecular pump with internal 4-stage diaphragm backing pump standard, corrosive gas pumping with all internal pumps optional
Automated Inlet Pressure Controller
A Baratron® capacitance manometer-based automated inlet pressure controller is available as an option
PC Requirements
Microsoft 32 bit or 64 bit Windows 7 or 8.1
Interfaces
1 x LAN port required
I/O Capability
4 analog inputs (-11 to +11 V, 22 bit), 2 analog outputs (0-10 V, 12 bit), 16 TTL digital I/O
Power Requirements
Universal mains input 100 - 240 VAC/50 - 60 Hz. Power supply specified at 700 W. Maximum consumption(during bakeout) typically 300 W
Compliance
Exempt to RoHS Directive 2002/95/EC
Dimensions
Benchtop: 593 x 291 x 470 mm, Rack-mounted: 577 x 482 x 266mm, (6U) (length x width x height)
Weight
Benchtop: 35 kg, Rack-mounted: 35 kg
Measurement Technique
Mass Spectrometry
Detector
Dual (Faraday and Secondary Electron Multiplier)
Technical Specs
Type
ATM-pressure Gas Monitor
Mass Range
1 - 100 amu, 1 - 200 amu, or 1 - 300 amu
Minimum Detectable Concentration
Gas and Mass Independent. The minimum detectable concentration 3 sigma baseline noise is <15 ppb (specified with Argon or Nitrogen)
180°C for bake out, 80°C setting for operation at elevated temperatures (vacuum chamber & inlet interface)
Inlet
2.0 m long with 0.25 in. Swagelok® end connection, heated to 150°C (optional heating to 300°C, with stainless steel only). Standard fused silica and optional stainless steel.
Gas Consumption
20 ml/min, lower uptake rate capillaries options are available
Sample Pressure
1 bar nominal
Pumping System
High compression turbo-molecular pump with internal 4-stage diaphragm backing pump standard, corrosive gas pumping with all internal pumps optional
Automated Inlet Pressure Controller
A Baratron® capacitance manometer-based automated inlet pressure controller is available as an option
PC Requirements
Microsoft 32 bit or 64 bit Windows 7 or 8.1
Interfaces
1 x LAN port required
I/O Capability
4 analog inputs (-11 to +11 V, 22 bit), 2 analog outputs (0-10 V, 12 bit), 16 TTL digital I/O
Power Requirements
Universal mains input 100 - 240 VAC/50 - 60 Hz. Power supply specified at 700 W. Maximum consumption(during bakeout) typically 300 W
Compliance
Exempt to RoHS Directive 2002/95/EC
Dimensions
Benchtop: 593 x 291 x 470 mm, Rack-mounted: 577 x 482 x 266mm, (6U) (length x width x height)
Additional CAD file downloads are not available for this product.
CIRRUS-3-XD - Drawings
Additional drawings are not available for this product.
CIRRUS-3-XD
Sign In
Password Reset
Enter your email address below to reset your account password.
Password Reset
Email Verification Required
Cart Items Updated
Remove Product
Remove this product from your comparison list?
Check Order Status
Provide an order number and postal code to check the status of an order or download an invoice for an order that has shipped. Login to view your complete order history.
Sign In Required
To access this and other valuable technical resources, please sign in or register for a new online account.
Add to Cart
Atmospheric Gas Analyzer, Quadrupole Mass Spectrometry, Cirrus 3-XD, V-lens