500 Cold Cathode Vacuum Transducers
Model: 500100-2C-R4G-M
500 Cold Cathode Vacuum Transducers
Model: 500100-2C-R4G-M

Overview
Overview
The 500100-2C-R4G-M Cold Cathode Gauge features a 2.75 inch CF flange and a 1x10-10 to 1x10-2 Torr vacuum measurement range with mbar units. This high accuracy version is calibrated for +/- 10% accuracy. An included RS-485 communications interface and analog output signal features programmable off state, start point, and slope. Two programmable set point relays are also included. The 500 series incorporates the latest technology with modern design techniques to provide highly reliable and long life vacuum measurement across a wide pressure range. The modular design integrates gauge and control electronics in one convenient package. Cold cathode technology traditionally provides longer lifetime than hot cathode because there is no filament to burn out, but the tradeoff was reduced accuracy. The Series 500 Cold Cathode Gauge (CCG) defines a new accuracy standard based on innovative technology and time-tested calibration techniques. In addition, there has never been a good way to determine when a cold cathode gauge is worn to the point that its accuracy has significantly degraded. With a new patent-pending method of determining the pressure dosage over time and combining that with a user-selected environmental factor, the CCG Series 500 provides an indication of when the gauge needs to be serviced or replaced.
Technical Specs
- Absolute Measurement Range1.0 x 10-10 to 0.01 Torr
- Digital CommunicationRS485
- TypeVacuum Gauge Module
- DisplayNo
- InterfaceRS485/analog
- Relays2
- Fitting Type2.75 in. CF
- Installation OrientationAny
- Operating Temperature0 - 50°C
- Maximum Bakeout Temperature250°C (magnets removed)
- Storage Temperature-40 - 70°C
- Analog Output0-11 VDC (LOG10)
- Power Requirements13.5 - 36 VDC, <2 Watts
- AccuracyHigh (calibrated): 1 x 10-8 to 1 X 10-4 Torr ±10%
- Repeatability1 x 10-8 to 1 X 10-4 Torr ±5% (typical)
- Exposed Materials304 Stainless Steel, 17-7 stainless steel, ceramic, Cu brazing material, alumina, and molybdenum
- Weight652 grams
- ComplianceCE
- Set Point Contact RatingMax 1A@30 VDC, Min 5ma at 5 VDC, maximum ripple 1Vpp
- USB PortMicro-AB
- Unitsmbar
- Analog Output Voltage0 - 11 VDC (log)
- Analog Output Minimum Impedance200 Ohm
- Analog Output Minimum Load Impedance10 kOhm
- Analog Output Minimum Update Rate40 Hz
- Analog Input Signal Voltage0 - 11 VDC
- Digital Baud Rates1200-115,200 Baud
- Overpressure ProtectionControlled by an external gauge and/or measured pressure
Technical Specs
- Absolute Measurement Range1.0 x 10-10 to 0.01 Torr
- Digital CommunicationRS485
- TypeVacuum Gauge Module
- DisplayNo
- InterfaceRS485/analog
- Relays2
- Fitting Type2.75 in. CF
- Installation OrientationAny
- Operating Temperature0 - 50°C
- Maximum Bakeout Temperature250°C (magnets removed)
- Storage Temperature-40 - 70°C
- Analog Output0-11 VDC (LOG10)
- Power Requirements13.5 - 36 VDC, <2 Watts
- AccuracyHigh (calibrated): 1 x 10-8 to 1 X 10-4 Torr ±10%
- Repeatability1 x 10-8 to 1 X 10-4 Torr ±5% (typical)
- Exposed Materials304 Stainless Steel, 17-7 stainless steel, ceramic, Cu brazing material, alumina, and molybdenum
- Weight652 grams
- ComplianceCE
- Set Point Contact RatingMax 1A@30 VDC, Min 5ma at 5 VDC, maximum ripple 1Vpp
- USB PortMicro-AB
- Unitsmbar
- Analog Output Voltage0 - 11 VDC (log)
- Analog Output Minimum Impedance200 Ohm
- Analog Output Minimum Load Impedance10 kOhm
- Analog Output Minimum Update Rate40 Hz
- Analog Input Signal Voltage0 - 11 VDC
- Digital Baud Rates1200-115,200 Baud
- Overpressure ProtectionControlled by an external gauge and/or measured pressure