307 Bayard-Alpert Vacuum Gauge Controller
Model: 307501-000-M3
307 Bayard-Alpert Vacuum Gauge Controller
Model: 307501-000-M3

Overview
Overview
The 307501-000-M3 Vacuum Gauge Controller is configured for Series 274 glass tubulated or nude (not UHV) Bayard-Alpert gauges with resistive degas and comes with a half rack mount and remote power supply. It displays mBar measurement units, and is powered by 220 VAC with an EU power cord. Series 307 controllers measure pressure, and utilizes pressure related outputs to control a variety of vacuum system functions and processes.
Technical Specs
- TypeVacuum Gauge Controller
- Measurement Range7 decades within above limits for given emission setting and tube sensitivity
- Lower Measurement Limit1 x 10-10 Torr with 10 mA emission and tube sensitivity of 10/Torr
- Upper Measurement Limit2 x 10-2 Torr with 0.1 mA emission and tube sensitivity of 10/Torr
- DisplayDigital (green LED)
- Display Update Rate0.5 second typical
- Unitsmbar
- Compatible with274 Ionization Gauge
- Electrical PlugEurope 220 VAC
- Power Requirements100/115/230 ±10% VAC, 250 Watts, 50 or 60 Hz
- InterfaceNo
- Relays0
- Emission CurrentControlled, adjustable from 0.01 to 10.0 mA
- DegasElectron Bombardment: 10 - 40 Watts adjustable, resistive (I2 R): 8 Volts nominal, (fixed) 80 Watts maximum
- Operating Temperature40°C maximum, ambient
- MountingRemote power supply
- OutputLogarithmic: 1 volt/decade, 0 - 10 VDC, analog
- Lower Measurement Limit with UHV2 x 10-11 Torr with 10 mA emission and tube sensitivity of 25/Torr
Technical Specs
- TypeVacuum Gauge Controller
- Measurement Range7 decades within above limits for given emission setting and tube sensitivity
- Lower Measurement Limit1 x 10-10 Torr with 10 mA emission and tube sensitivity of 10/Torr
- Upper Measurement Limit2 x 10-2 Torr with 0.1 mA emission and tube sensitivity of 10/Torr
- DisplayDigital (green LED)
- Display Update Rate0.5 second typical
- Unitsmbar
- Compatible with274 Ionization Gauge
- Electrical PlugEurope 220 VAC
- Power Requirements100/115/230 ±10% VAC, 250 Watts, 50 or 60 Hz
- InterfaceNo
- Relays0
- Emission CurrentControlled, adjustable from 0.01 to 10.0 mA
- DegasElectron Bombardment: 10 - 40 Watts adjustable, resistive (I2 R): 8 Volts nominal, (fixed) 80 Watts maximum
- Operating Temperature40°C maximum, ambient
- MountingRemote power supply
- OutputLogarithmic: 1 volt/decade, 0 - 10 VDC, analog
- Lower Measurement Limit with UHV2 x 10-11 Torr with 10 mA emission and tube sensitivity of 25/Torr
Resources & Downloads
Literature
307 Bayard-Alpert Gauge Controller(300 kB, PDF)