Sorry, this product is no longer offered for sale.
226A Baratron® 0.2-1000 Torr Differential Capacitance Manometers
Model: 226A11TBBBBFB2A1
226A Baratron® 0.2-1000 Torr Differential Capacitance Manometers
Model: 226A11TBBBBFB2A1

Overview
Overview
The 226A11TBBBBFB2A1 Baratron® differential capacitance manometer is ranged for 10 Torr, has 0.25 inch OD reference and measurement side tubes, 0.50% of Full Scale accuracy, ±15 VDC input and 0 - 10 VDC analog output with bidirectional calibration, a 9-pin type "D" subminiature electrical connector and a standard mounting bracket. It is mounted in a rugged industrial-grade housing that minimizes external RF/EM interference on the electronics and when properly configured, is completely "drop-in" compatible with earlier Baratron® differential manometers.
Technical Specs
- TypePressure Transducer
- Sensor TypeCapacitance Manometer
- Measurement TypeDifferential
- Full Scale Range10 Torr
- Analog Output0 - 10 VDC
- CalibrationBidirectional
- Fitting Type0.25 in. OD tube
- Electrical Connector9-pin D-sub
- Resolution0.01% of Full Scale
- Accuracy0.50% of Full Scale
- Zero Temperature Coefficient0.1% Full Scale/°C for standard accuracy specification
- Span Temperature Coefficient0.04% of Reading/°C
- Sensor Internal VolumeMeasurement Side: 1.4 cm3, Reference Side: 9.0 cm3
- Operating Temperature Range0° to 50°C
- Maximum OverpressureMeasurement Side: 120% of Full Scale or 20 psi (140 kPa), whichever is higher, Reference Side: 120% of Full Scale
- Maximum Line Pressure40 psig (275 kPa)
- Exposed MaterialsMeasurement Side: Inconel, Reference Side: Inconel, ceramic, palladium, stainless steel, glass
- Measurement Side Fitting0.25 in. OD tube
- Reference Side Fitting0.25 in. OD tube
- Mounting BracketStandard
- Trip Points1
- Power Requirements±15 VDC
- ComplianceCE, SEMI S2-0706
Technical Specs
- TypePressure Transducer
- Sensor TypeCapacitance Manometer
- Measurement TypeDifferential
- Full Scale Range10 Torr
- Analog Output0 - 10 VDC
- CalibrationBidirectional
- Fitting Type0.25 in. OD tube
- Electrical Connector9-pin D-sub
- Resolution0.01% of Full Scale
- Accuracy0.50% of Full Scale
- Zero Temperature Coefficient0.1% Full Scale/°C for standard accuracy specification
- Span Temperature Coefficient0.04% of Reading/°C
- Sensor Internal VolumeMeasurement Side: 1.4 cm3, Reference Side: 9.0 cm3
- Operating Temperature Range0° to 50°C
- Maximum OverpressureMeasurement Side: 120% of Full Scale or 20 psi (140 kPa), whichever is higher, Reference Side: 120% of Full Scale
- Maximum Line Pressure40 psig (275 kPa)
- Exposed MaterialsMeasurement Side: Inconel, Reference Side: Inconel, ceramic, palladium, stainless steel, glass
- Measurement Side Fitting0.25 in. OD tube
- Reference Side Fitting0.25 in. OD tube
- Mounting BracketStandard
- Trip Points1
- Power Requirements±15 VDC
- ComplianceCE, SEMI S2-0706