The PFC-20, Low Pressure πMFC mass flow controller provides maximum utilization of Safe Delivery Source gases. Implementation of the Low Pressure πMFC increases tool uptime by reducing the frequency of source gas cylinder changes.
Specifications
- Full Scale Flow Range2 - 20 sccm (N2 equivalent)
- Inlet Pressure Range4 - 1200 Torr (with vacuum at the outlet)
- Normal Operating Pressure Differential<10 Torr at Full Scale flow (with vacuum at the outlet)
- Burst Pressure1500 psig
- Control Range2 to 100% of Full Scale
- Typical Accuracy±1% of set point for >10 to 100% Full Scale
±0.2% of Full Scale for 2 to 10% of Full Scale - Repeatability0.2% of Full Scale
- Resolution0.1% of Reading
- Zero Temperature Coefficient±0.08% of Full Scale /°C
- Span Temperature Coefficient±0.08% of Reading/°C
- Typical Settling Time<2 sec. typical above 10% of Full Scale at inlet pressures >10 Torr
- Warm-up Time30 minutes
- Operating Temperature10 to 50°C
- Storage Humidity0 to 95% Relative Humidity, non condensing
- Storage Temperature-20 to 65°C
- Temperature Display0 to 100°C
- Temperature Accuracy±2°C
- Temperature Resolution0.1°C
- Display4 digits for value, 4 characters for unit
- Fitting TypeSwagelok® 4 VCR®
- External Leak Integrity<1x10
(scc/sec He) - Leak Integrity Through Closed Valve<1.0% of FS at 25 psig to atmosphere
- Wetted Materials316 S.S. VAR, 316 S.S., Elgiloy, KM-45, NiTi (Standard)
- Surface Finish5 microinch average Ra
- Weight2 lbs. (0.9 kg)
- Power Requirements15-24 VDC ±5%VDC @ 350mA peak, 250 mA steady state
- Analog I/O Connector9 pin "D" male or 15 pin "D" male
- Set Point Command Signal0 to 5 VDC
- Flow Input Output Signal0 to 5 VDC