Sorry, this product is no longer offered for sale. The recommended replacement product is 627h-heated-capacitance-manometers.
627F 0.02-25,000 Torr, Heated (45°C) Absolute Baratron® Capacitance Manometers
Model: 627f-heated-capacitance-manometers
627F 0.02-25,000 Torr, Heated (45°C) Absolute Baratron® Capacitance Manometers
Model: 627f-heated-capacitance-manometers

Overview
Overview
Technical Specs
- TypePressure Transducer
- Sensor TypeCapacitance Manometer
- Measurement TypeAbsolute
- Sensor TemperatureControlled to 45°C
- Full Scale Pressure Ranges0.02, 0.05, 0.1, 0.25, 1, 2, 10, 20, 100, 1000, 2000, 5000, 10000, 15 000, 20000, 25000 Torr
- Accuracy0.12% of Reading
0.15% for 0.25, 0.1, and 0.05 Torr - Resolution0.001% of Full Scale
0.002% of Full Scale for 0.02 and 0.05 Torr - Analog Output0 - 10 VDC into >10K Ω load
- Zero Temperature Coefficient0.002% of Full Scale/°C for 1 - 25000 Torr range
0.005% Full Scale/°C for 0.25 and 0.1 Torr
0.015% Full Scale/°C for 0.05 Torr
0.03% Full Scale/°C for 0.02 Torr - Span Temperature Coefficient0.02% of Reading/°C
- Ambient Operating Temperature15° to 40°C
- Volume6.3 cc
- Warm-up Time2 hours for 25000 Torr Full Scale, 4 hours for 0.1 Torr Full Scale and lower
- Overpressure Limit45 psia (310 kPa) or 120% Full Scale, whichever is greater
- Materials Exposed to Process GasesInconel®
- Power Requirements±15 VDC ±5% @ 0.25 Amps (maximum)
- ComplianceCE
Technical Specs
- TypePressure Transducer
- Sensor TypeCapacitance Manometer
- Measurement TypeAbsolute
- Sensor TemperatureControlled to 45°C
- Full Scale Pressure Ranges0.02, 0.05, 0.1, 0.25, 1, 2, 10, 20, 100, 1000, 2000, 5000, 10000, 15 000, 20000, 25000 Torr
- Accuracy0.12% of Reading
0.15% for 0.25, 0.1, and 0.05 Torr - Resolution0.001% of Full Scale
0.002% of Full Scale for 0.02 and 0.05 Torr - Analog Output0 - 10 VDC into >10K Ω load
- Zero Temperature Coefficient0.002% of Full Scale/°C for 1 - 25000 Torr range
0.005% Full Scale/°C for 0.25 and 0.1 Torr
0.015% Full Scale/°C for 0.05 Torr
0.03% Full Scale/°C for 0.02 Torr - Span Temperature Coefficient0.02% of Reading/°C
- Ambient Operating Temperature15° to 40°C
- Volume6.3 cc
- Warm-up Time2 hours for 25000 Torr Full Scale, 4 hours for 0.1 Torr Full Scale and lower
- Overpressure Limit45 psia (310 kPa) or 120% Full Scale, whichever is greater
- Materials Exposed to Process GasesInconel®
- Power Requirements±15 VDC ±5% @ 0.25 Amps (maximum)
- ComplianceCE
Resources & Downloads
Manuals
627F Baratron® Capacitance Manometer (1073260-001)(543.1 kB, PDF) 626, 627, 628, E27 & E28 Capacitance Manometer Pin-outs(22.4 kB, PDF)
Literature
Drawings & CADs
627 Dimensional Drawing(125 kB, PDF)