Sorry, this product is no longer offered for sale.

Temperature Input Module, 8 Thermocouple or PT100 RTD, Removable Terminal

Technical Specs

  • Type
    Temperature Input Module
  • ADC Native Resolution
    16-bit
  • Number of Inputs
    8
  • Main Power Supply
    24 V
  • Connector
    Removable Terminal
  • Control Accuracy
    0.1°C (depending on input)
  • Input Stability
    0.08°C for RTDs, 0.1°C for T/Cs
  • Input Resolution
    0.01°C (depending on input)
  • Maximum Power Consumption per Module
    24 V_IO@ 0.25 Amp, 24 V_CORE@ 0.15 Amp
  • Sampling Rate
    Configurable from 1.6 Hz to 13 Hz
  • Thermocouple Type
    2-wire, Thermocouples (J, K, or N - software configurable), 3-wire resistance temperature detectors (RTDs, factory configured), PT100 (-200 - 715°C), PT1000 (-200 - 850°C)
  • Operating Temperature
    0 - 55°C, with 2°C upper limit reduction per 1000 ft above sea level
  • Storage Temperature
    -40 - 85°C
  • Altitude
    0-10,000 ft above sea level
  • Humidity
    5 - 85% non-condensing
  • Vibration
    2.5 g acceleration over 5 - 300 Hz sine wave, 1 octave/Minimum sine sweep
  • Shock
    30 g, 11 msec duration, half-sine shock pulse
  • Dimensions
    35 x 125 x 92.3 mm (1.4 x 3.3 x 4.9 in.)
  • Mounting
    DIN rail
  • Compliance
    EMC Emissions: EN 61000-6-2: 2005

Need help?

Contact an Applications Specialist by sending us an email