; Slave GSD File for MKS flow controller ;======================================== #Profibus_DP GSD_Revision=5 Vendor_Name = "MKS" Model_Name = "MKS_MFC" Revision = "V1.0" Ident_Number = 0x0930 Protocol_Ident = 0 ; PROFIBUS DP Station_Type = 0 ; DP Slave FMS_supp = 0 ; FMS is not supported Hardware_Release = "V11" Software_Release = "V020313" ;>>> supported Baudrate 9.6_supp=1 19.2_supp=1 45.45_supp=1 93.75_supp=1 187.5_supp=1 500_supp=1 1.5M_supp=1 3M_supp=1 6M_supp=1 12M_supp=1 MaxTsdr_9.6=15 MaxTsdr_19.2=15 MaxTsdr_45.45=15 MaxTsdr_93.75=15 MaxTsdr_187.5=15 MaxTsdr_500=15 MaxTsdr_1.5M=20 MaxTsdr_3M=35 MaxTsdr_6M=50 MaxTsdr_12M=95 Redundancy = 0 ; no system Redundancy Repeater_Ctrl_Sig = 2 ; TTL level 24V_Pins = 0 ; not connected ;>>> Slave Parameter Slave_Family=0@MKSINST Freeze_Mode_supp = 1 ; Freeze Mode supported Sync_Mode_supp = 1 ; Sync Mode supported Auto_Baud_supp = 1 ; automatic Baudrate Search supported Set_Slave_Add_supp = 1 ; SetSlaveAdr supported Max_User_Prm_Data_Len=19 Ext_User_Prm_Data_Const(0)=0x80,0x00,0x00,\ 0x00,0x0f,0x42,0x40,0x00,0x00,0x00,0x00,0x00,0x0d,0xbb,0xa0,0x00,0x01,0x86,0xa0 ; float data format signed integer Min_Slave_Intervall = 1 ; in 100 ys DPV1_Slave = 1 C1_Read_Write_supp = 1 C2_Read_Write_supp = 0 C1_Max_Data_Len = 240 C2_Max_Data_Len = 0 C1_Response_Timeout = 10 ;C2_Response_Timeout = 0 C1_Read_Write_required = 0 C2_Read_Write_required = 0 C2_Max_Count_Channels = 0 Max_Initiate_PDU_Length = 0 Diagnostic_Alarm_supp = 0 Process_Alarm_supp = 0 Pull_Plug_Alarm_supp = 0 Status_Alarm_supp = 0 Update_Alarm_supp = 0 Manufacturer_Specific_Alarm_supp = 0 Extra_Alarm_SAP_supp = 0 Alarm_Sequence_Mode_Count = 0 Alarm_Type_Mode_supp = 0 Diagnostic_Alarm_required = 0 Process_Alarm_required = 0 Pull_Plug_Alarm_required = 0 Status_Alarm_required = 0 Update_Alarm_required = 0 Manufacturer_Specific_Alarm_required = 0 DPV1_Data_Types = 0 WD_Base_1ms_supp = 1 Check_Cfg_Mode = 0 Modular_Station = 0 ; it is no modular Station Max_Diag_Data_Len=128 ;>>> Device diagnostic Module = "SMALL_MFC" 0x91, 0xD5, 0xA1, 0xE1 ; small send/receive 1 EndModule